04 Hadron Accelerators
A12 Fixed-Field Alternating Gradient Accelerators
Paper Title Page
TUPAL030 Improvement of RF Capture with Multi-Turn H Injection in KURRI FFAG Synchrotron 1066
 
  • T. Uesugi, Y. Fuwa, Y. Ishi, Y. Kuriyama, Y. Mori, H. Okita
    Kyoto University, Research Reactor Institute, Osaka, Japan
 
  In the KURRI FFAG synchrotron, charge-exchanging multi-turn injection is adopted with a stripping foil located on the closed orbit of injection energy. No injection bump orbit system is used and the beam escapes from the foil according to the closed-orbit shift by acceleration. The particles hit the foil many times and the emittance grows up during the injection. In this paper, the capture efficiencies are studied with different rf process, including adiabatic capture.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAL030  